Load....
TGA certification! Huada Zhizao's remote ultrasound robot has been granted market access in Australia
MoreDNBSEQ-T20×2
Order NowProvide tools for the research and application of multi omics in human health and diseases
Running 6 loads simultaneously
30X coverage rate>50000WGS/year
Running 6 loads simultaneously
30X coverage rate>50000WGS/year
Running 6 loads simultaneously
30X coverage rate>50000WGS/year
Running 6 loads simultaneously
30X coverage rate>50000WGS/year
Massive increase in flux
30x Coverage
Massive increase in flux
30x Coverage
Sequencing read length
Effective Reads/Load
Single run flux
Sequencing time
Q30 (%)
Sequencing read length
Effective Reads/Load
Single run flux
Sequencing time
Q30 (%)
Provide tools for the research and application of multi omics in human health and diseases
Provide tools for the research and application of multi omics in human health and diseases
Product model | DNBSEQ-T20×2RS |
Number of slides/ Run | 6 |
Effective reads/load | 35 B (PE100) 40 B (PE150) |
Supports read length | PE100 PE150 |
* The maximum number of valid reads is obtained based on the specific standard library operation, and the actual application library may fluctuate depending on the sample type and library construction method. |
Supports read length | Data output | Data quality Q30* | Run time** |
PE100 | ~42 Tb | ≥85% | ~60 h |
Effective reads/load | 35 B (PE100) 40 B (PE150) | Number of slides/ Run | 6 |
* The base percentage above Q30 is the average of the internal standard library throughout the entire run. The actual performance is influenced by factors such as sample type, library quality, and insertion fragment length. | |||
** The running time includes on-chip operation, sequencing, and generating Cal. files. Cal. is a binary file format generated by Huada Zhizao sequencer basecall software. The generation of FASTQ files does not take up the time of the sequencer. | |||
*** PE150 will be launched in H2 in 2023. |
Provide tools for the research and application of multi omics in human health and diseases
Source&Size&Net Weight | |
---|---|
Maximum Power | 20000 VA |
Size | 4200 mm (L)* 4800 mm (W) * 2000 mm (H) |
Net Weight | 3700 kg (Not including BIT module) |
Laboratory load-bearing capacity | 500 kg/m2 |
Operating environment | |
Ambient Temperature | 19°C~22°C |
Relative Humidity | 30% RH ~ 70% RH |
Pressure Range | 90 kPa~106 kPa |
Pollution Level | Level 2 |
*Indoor use only | |
Source&Size&Net Weight | |
Power Supply Type | 380/400 V, 50 Hz |
Power Supply Type | 380/400 V, 50 Hz |
Power Supply Type | 380/400 V, 50 Hz |
Power Supply Type | 380/400 V, 50 Hz |
Provide tools for the research and application of multi omics in human health and diseases
Product number: 940-001323-00; 940-001324-00;940-001323-00;940-001324-00
Product number: 940-001323-00; 940-001324-00;940-001323-00;940-001324-00
Product number: 940-001323-00; 940-001324-00;940-001323-00;940-001324-00
Provide tools for the research and application of multi omics in human health and diseases
Macrogenomic Sequencing
MGISP-100 or MGISP-960
Library construction: MGIEasy Fast enzyme digestion library preparation kit V2.0
DNBSEQ one-step DNB preparation kit V2.0 (OS-DB)
DNBSEQ-G99
MGISEQ-200
DNBSEQ-E25
MGISEQ-2000
DNBSEQ-T7
DNBSEQ-T10×4
Microbial Rapid Identification Platform (PFI)
Human Genome Resequencing
MGISP-100 or MGISP-960
Library construction: MGIEasy Fast enzyme digestion library preparation kit V2.0
DNBSEQ one-step DNB preparation kit V2.0 (OS-DB)
MGISEQ-2000
DNBSEQ-T7
DNBSEQ-T10×4
DNBSEQ-T20×2
MegaBOLT
- WGS Germline Variation Detection Process
- WGS Somatic Variation Detection Process
Human Exome Sequencing
MGISP-100 or MGISP-960
Library construction: MGIEasy Fast enzyme digestion library preparation kit V2.0
DNBSEQ one-step DNB preparation kit V2.0 (OS-DB)
MGISEQ-2000
DNBSEQ-T7
MegaBOLT
- WGS Germline Variation Detection Process
- WGS Somatic Variation Detection Process
Animal and plant genome resequencing (can be used for molecular breeding, population evolution research, etc.)
MGISP-100 or MGISP-960
Library construction: MGIEasy Fast enzyme digestion library preparation kit V2.0
DNBSEQ one-step DNB preparation kit V2.0 (OS-DB)
MGISEQ-2000
DNBSEQ-T7
DNBSEQ-T10×4
DNBSEQ-T20×2
A comprehensive and professional software and hardware integration solution
Provide tools for the research and application of multi omics in human health and diseases
More
More
More
Provide tools for the research and application of multi omics in human health and diseases
Shenzhen Huada Zhizao Technology Co., Ltd. (referred to as Huada Zhizao) adheres to the concept of "innovative intelligent manufacturing leading life technology", and is committed to becoming a core tool creator of life technology. It focuses on the fields of life science and biotechnology, and its main business is the research and development, production, and sales of instruments, equipment, reagents, consumables, and other related products. It provides real-time, panoramic, and full lifecycle life digital equipment and systems for industries such as precision medicine, precision agriculture, and precision health. Founded in 2016, as of September 30, 2023, Huada Zhizao has 2900 employees, with R&D personnel accounting for about 36%. Its business layout covers more than 100 countries and regions on six continents, and it has served more than 2600 users worldwide. It has established research and production bases, training and after-sales service centers in multiple countries and regions around the world, and has become one of the few clinical grade gene sequencer enterprises in the world that can independently develop and mass produce different fluxes from Gb level to Tb level.
Online
Consultation